This website uses cookies

We use cookies to show you the right content for your language and devices (Necessary), to present content selected for you (Preferences), to analyse traffic to our website (Statistics) and to offer you our best special offers on other websites (Marketing).

By clicking on "ACCEPT", you consent to the use of cookies. You can change or revoke your cookie settings at any time in the footer under "Cookie settings". You can find detailed information in our privacy policy.

  • These cookies are necessary for the functionality of our website and cannot be deactivated (e.g. session cookies).

  • These cookies make it possible, among other things, to display your previously viewed articles and to recommend similar articles. Further information can be found in our privacy policy and that of the respective provider;

  • These cookies help us to understand how visitors interact with our website. The information is collected and analyzed anonymously. Depending on the tool, one or more cookies from the same provider are set. Further information can be found in our privacy policy and that of the respective provider;

  • We need these cookies to show you our advertising on other websites, for example. If you deactivate them, you will be shown other advertising instead. Further information can be found in our privacy policy and that of the respective provider;

In order to design our website optimally for you and to be able to improve it continuously, we use cookies. By continuing to use the website, you agree to the use of cookies. For more information on cookies, please see our privacy policy.

Skip to content

Portable Site Power Distributor with all-current sensitive RCD Type B (32A CEE plug, 2m RN cable, sockets: 1x CEE 400V/32A, 2x CEE 400V/16A, 4x earthed sockets 230V, complies with DIN VDE 0100-704, Made in Germany)

Hugo Brennenstuhl GmbH & Co Kommanditgesellschaft Power distributors
Article number 1154900629
EAN 4007123687398
Article number 1154900629
EAN 4007123687398

Description

Description

The portable power distributor with 2m oil-resistant RN cable (H07RN-F 5G6.0) serves to increase safety for people and the environment on construction sites thanks to the type B residual current device. This RCD is based on the VDE 0100-704:2018-10 standard and will ensure even more safety on construction sites in the future. The type B residual current device is required because smooth or nearly smooth DC residual currents occur that are not detected by a type A residual current device. Comprehensive personal and system protection is therefore only guaranteed with an all-current sensitive residual current device type B. The practical and extremely robust current distributor with protective covers for fuses also convinces with the following features:

  • Robust and plastic-coated tubular steel frame
  • Ergonomically shaped carrying handle for comfortable transport
  • Practical rewinding device for the connection cable on the rear side
  • Oil-resistant rubber cable for permanent outdoor use
  • Cable designation: H07RN-F 5G6.0
  • Cable length: 2m
  • Protection class: IP44
  • Number of poles (FI): 4
  • With RCD (type B all-current sensitive) - personal protection switch 30 mA for more safety
  • Number of circuit breakers: 5 (1x LS 400V/16A 3-pole/-pin; 4x LS 230V/16A 1-pole/-pin)
  • Plug: CEE 32A 3P+N+PE (5p) 400V
  • CEE socket - 16 A: CEE 2x 16A 3P+N+PE (5p) 400V
  • CEE socket outlet - 32 A: CEE 1x 32A 3P+N+PE (5p) 400V
  • Earthed sockets: 4
RCD personal protection switch
RCD personal protection switch

A residual current circuit breaker (RCD) is an electrical protective device used primarily to protect against electric shocks. The RCD detects the difference between the incoming and outgoing current in a circuit. If a fault current occurs, for example due to an insulation fault or a current flow via an unwanted discharge such as a person, the RCD switches off the circuit. This significantly reduces the risk of electric shock or fire caused by a fault current. When used as personal protection, a residual current device must trip and interrupt the circuit at a residual current of 30mA at the latest.

Technical data
Downloads